Mark6 recording

From $1

    Version as of 02:04, 18 Apr 2025

    to this version.

    Return to Version archive.

    View current version

    Preparation

    • Make sure R2DBE slot0 channel 0 output is connected to Mark6 eth3 interface
    • Make sure R2DBE slot0 channel 1 output is connected to Mark6 eth5 interface
    • Install the most recent Mark6 software (instructions)
    • make sure dplane and cplane programs have been started

    Module loading

    • insert 4 modules into the 4 slots of the Mark6 recorder
    • connect the miniSAS cables. Make sure the number on the cable tray matches the slot number. Make sure the red and yellow dots on the cables match the dots on the recorder.
    • Turn the key into the horizontal position on slot 1. Be patient...there will be LED activity on the module finally the "Ready" LED on the slot should light up in green. Now proceed to the next module until all 4 modules are in the "Ready state"

    Module initialization

    Note: This procedure will delete all the content on the disk modules. Make sure you have loaded the correct modules!

    in da_client execute:

    mod_init=1:8:MPIH%008:sg:new
    

    This will initialize the module in slot 1 with the MSN: MPIH%008 (substitute with the MSN found on the sticker of the module in slot 1). During intialization the LEDs on the module in slot 1 should light up one by one. If you see activity in a different slot you have an error in the cabeling and need to review the mini-SAS connections on the backside of your Mark6 unit.

    Now do the initialization for the other 3 modules:

    mod_init=2:8:MPIH%005:sg:new
    mod_init=3:8:MPIH%007:sg:new
    mod_init=4:8:MPIH%006:sg:new
    

    Check that initialization was successfull:

    mstat?all
    

    This should something like this:

    !mstat?0:0:-:1:MPIH%008/48008/4/8:8:8:-:48008:initialized:null:sg:-:2:MPIH%005/48008/4/8:8:8:-:48008:initialized:null:sg:-:3:MPIH%007/48008/4/8:8:8:-:48008:initialized:null:sg:-:4:MPIH%006/48008/4/8:8:8:-:48008:initialized:null:sg;
    

    Make sure the MSNs are correct and that all modules have the state "initialized"

    Important: PUT A STICKER on the disk modules now with the following content:

    Create a 4-module group

    in da_client execute:

    group=new:1234
    
    mstat?1
    mstat?2
    mstat?3
    mstat?4
    

    This should list:                                                                                              

    !mstat?0:0:1234:1:MPIH%008/48008/4/8:8:8:0:48008:closed:unprotected:sg;
    !mstat?0:0:1234:2:MPIH%005/48008/4/8:8:8:0:48008:closed:unprotected:sg;
    !mstat?0:0:1234:3:MPIH%007/48008/4/8:8:8:0:48008:closed:unprotected:sg;
    !mstat?0:0:1234:4:MPIH%006/48008/4/8:8:8:0:48008:closed:unprotected:sg;
    

    Make sure the 3rd column contains the newly formed group 1234 and that the state is "closed" for all 4 modules.

    Define input streams

    in da_client execute:

    input_stream=add:RDBE1:vdif:8224:50:42:eth3:172.16.3.1:0:12
    input_stream=add:RDBE2:vdif:8224:50:42:eth5:172.16.5.1:0:34
    input_stream=commit
    

    Open the group for recording

    in da_client execute:

    group=open:1234
    mstat?all
    

    All 4 modules should now be in the "open" state.

    The modules are now ready for recording.


     